Options for venting a bathroom exhaust fan include best to worst.
Can you exhaust bath fan into attic.
It seems like such an easy solution just leave a bathroom vent hose in an attic.
All the moisture from your bathroom will be discharged into the garage.
The exhaust needs to vent outdoors.
After a while all that moisture will condense on this equipment and this is a recipe for disaster.
Can i vent a bathroom fan into my attic.
In those areas ventilation in bathrooms is required but it can be from a window or fan your choice.
If you re simply replacing the fan the ducts should already be set up for you.
Bathroom ventilation fan duct routing routing a bath vent duct down out or up through an attic or roof out.
When venting a bathroom exhaust fan make sure to vent the air to the outside rather than into your attic where it can cause mold and mildew to form.
There aren t many options for routing an exhaust fan to the outside of the house.
Allowing the exhaust to vent into your attic can potentially cause several moisture problems.
Ductwork is what will connect the fan to the outside.
You should never exhaust the bathroom fan directly into the attic.
Before you can start replacing your old bathroom fan you ll need to determine what the fan size is.
However that is what you do when you vent the bathroom exhaust fan into the garage.
Your attic is not a temperature controlled environment is never the same temperature as your living space and generally closer to the temperature outside.
In no case is it acceptable to just dump any exhaust fan directly into an attic.
It needs to exhaust to the exterior.
There are really only three venting options.
In all cases the ducting needs to conduct the exchaust to the building exterior and needs to terminate in an animal proof vent cover.
No you should not vent a bathroom fan directly into an attic however you can vent a bathroom fan through an attic while it terminates on the roof or gable end.
Bathroom exhaust fans perform an important function by removing excess moisture from your home.
Surprisingly bathroom fans are not required by some building codes.
On 2020 02 26 by anonymous.
All municipalities have different requirements but some do not draw a hard line on requiring exhaust fans.
You d often blow air from one bathroom into the other and local building inspectors wouldn t approve it.
This article describes routing bath exhaust fan duct upwards through an attic or roof space or downwards through a floor or crawl space.
Anon if i understand your original question you have a bath exhaust that is discharging into a roof cavity or space not to outside.
This setup requires an in line centrifugal fan mounted in the attic drawing air simultaneously from both.